The DP6000 series medium-voltage harness testers support hybrid 2-wire/4-wire testing, Integrated with:
1. Fast & Precision OS (Open-Short) Testing
2. Continuity Testing
3. High-current continuity testing
4. DCR Testing
5. LCR Testing
6. Insulation resistance testing
7. AC/DC hipot testing
8. Maxium test points: DP6000(256 test points) / DP6000S(128 test points)
• Applications: Automotive PDU (Power Distribution Unit) validation, FPC (Flexible Printed Circuit) testing for EV batteries, medium-voltage harnesses testing with relatively higher voltage levels, etc.
1. Hybrid 2-Wire/4-Wire Testing – Combines methods for optimal accuracy.
2. Floating-Point Testing – Safely validates sensitive PCBs/FPCs without interference.
3. Maximum continuity test current: 1A.
4. Continuity resistance measurement range: 1μΩ~10Ω.
5. LCR Testing – 0~50kHz frequency, 0.1/0.3/1V test levels for component validation.
6. ESD Protection Test – 0~80V range with 1mA constant current excitation.
7. Insulation Resistance Test Range – ≥10GΩ.
8. Standard model: 10V~3000 V DC/10V~2000 V AC.
9. Distributed model (DP6000-D): Supports up to 20,480 test points
1. User management: Three-tier permission system (administrator/programmer/operator)
2. Project management: Categorized management for up to 500 configuration items
3. Network point self-learning: Automatically identifies connection relationships between points
4. Test segment partitioning: Supports both auto-learned and manual segmentation
5. Graphical editing: Configure points directly on connector diagrams
6. Test parameter configuration: Customizable settings for OS testing, insulation testing, etc.
7. System self-diagnostics: Facilitates fault diagnosis
8. Multimeter function: Available for any port
9. High-speed point location with voice announcement
10. PTC/NTC temperature conversion
11. 16-bit I/O port input/output control
12. Report printing & editing: Supports PDF and WORD formats
13. Database integration & MES connectivity
Product Application
Specification Category | Details | ||
Model | DP6000/DP6000S | ||
Measurement Method | Internal 4-wire + External 4-wire | ||
Maximum Test Points | 256/128 | ||
AC Output Voltage | 10V~2000V AC | ||
DC Output Voltage | 10V~3000V DC | ||
High Voltage Output Accuracy | ±3% | ||
High Voltage Measurement Accuracy | ±3% | ||
High Voltage Measurement Time | 0.1s~60s (excluding user delay) | ||
Low Voltage Measurement Time | 0.1s~60s (excluding user delay) | ||
OS Measurement Cycle | 5ms (1024 points, excluding user delay) | ||
Test Items and Range | O/S, Intermittence O/S, | 2kΩ~100kΩ | |
Internal 4-wire Continuity Resistance | 0.1Ω~1MΩ | ||
External 4-wire Continuity Resistance | Test range | 1μΩ~100Ω | |
Test current | ≤1A | ||
AC Hipot Leakage Current | 0.01mA~10mA | ||
DC Hipot Leakage Current | 0.1μA~5mA | ||
DC Hipot Insulation Resistance | 1MΩ~10GΩ | ||
DC Resistance | Measurement Range | 100mΩ~1MΩ | |
Level Signal | 0V~4V | ||
Current Signal | ≤2mA | ||
LCR | Capacitance Measurement Range | 10pF~100mF | |
Resistance Measurement Range | 100mΩ~20MΩ | ||
Inductance Measurement Range | 10nH~100H | ||
Frequency Signal | 50Hz/60Hz/100Hz/120Hz/1kHz/10kHz/50kHz | ||
Range Mode | AUTO/HOLD | ||
Level Signal | 0.1V/0.3V/1V | ||
Single-Side Test | Available | ||
Short/Open Circuit Endpoint Identification | Available | ||
Advanced Features | Programmable Continuous Test / Auto-Point Location / Auto Diagnostics | ||
Test Scan Modes | Auto / Manual / External Trigger | ||
Measurement Signal | Low Voltage Measurement Signal | ||
Storage Memory | Supports up to 500 Test Configuration Files | ||
OS Test Voltage | 5V | ||
Control Panel | System / Quick / Edit / Function Button Groups | ||
Indicators | Pass/Fail (LEDOptional) / On-Screen Display / Voice Broadcast | ||
Dimensions (mm) | 483 (W) × 265 (H) × 510 (D)/483 (W) × 183 (H) × 510 (D) | ||
Maximum Weight (kg) | 20/15(Max) |